Permits

Building department: Porter County Building Department (part of the Department of Development & Storm Water), 155 Indiana Avenue, Valparaiso, IN 46383; permit applications and questions (219) 465-3676; inspection scheduling (219) 465-3473. The county office handles building permits and inspections in unincorporated Porter County. The Town of Chesterton issues its own building permits through the Chesterton Building Department, 1490 Broadway, Suite 5, Chesterton (219-926-2610).

  • County permits and inspections. The Porter County Building Department processes applications for almost every building project and performs the follow-up inspections. Inspections are requested by phone at (219) 465-3473; callers who reach voicemail leave their name, phone number, jobsite address and permit number. Source
  • County contractor registration. Porter County requires every contractor to register in its online permitting portal (permitting.schneidergis.com, jurisdiction Porter County), where the contractor uploads a recorded bond and a certificate of general liability insurance and submits the application for approval. Source
  • Chesterton: plumbing and electrical always need a permit. Inside the Town of Chesterton, permits are issued by the town's Building Commissioner. Town code requires a permit before excavation, construction, alteration or repair of any building that involves a change of use, added lot coverage, or work above a job-cost threshold set in the ordinance, and it requires a permit for all plumbing and electrical construction, alteration or repair regardless of cost. Source
  • Chesterton permit types. Chesterton's permit schedule lists separate permit types for mechanical equipment (furnace, A/C, boiler, air handler), plumbing equipment (water heater, pumps, ejector pits), residential remodels, residential repair/replace work, and electrical service upgrades. Source
  • Chesterton: emergency repairs. In Chesterton, work started before a permit is issued is subject to a stop work order and a permit surcharge. The surcharge does not apply to emergency work done to prevent an imminent threat to people or structures if a permit is applied for within three business days after the emergency work. Source
  • Chesterton inspections. Chesterton's ordinance lists standard inspections that include underground electrical, electrical service, underground plumbing, rough plumbing, rough framing, rough mechanical, insulation, exterior plumbing and electric, and occupancy. Meeting state code alone is not enough: town requirements must also be met to pass inspection. Source
  • Chesterton registered contractors. The Chesterton Building Department posts a list of town-registered contractors (current as of Oct. 16, 2026) and notes that being on the list is not an endorsement and that some registrations may still be in process. Source
  • Codes enforced in Chesterton. Chesterton lists the codes it enforces, including the 2018 International Residential Code with 2020 Indiana amendments, the 2008 National Electrical Code with Indiana amendments, the 2006 International Plumbing Code with 2012 Indiana amendments, and the 2012 International Mechanical Code and International Fuel Gas Code with 2014 Indiana amendments. Source
  • Chesterton floodplain review. Before issuing a permit for major repairs in a special flood hazard area, Chesterton's Building Commissioner checks that the work uses flood-resistant materials and utility equipment and construction methods that limit flood damage. Site plans next to or in a floodplain must be prepared by a professional engineer licensed in Indiana. Source
  • Indiana plumbing license. Indiana law makes it unlawful to act as a plumbing contractor or journeyman plumber without a state license, and a corporation in the plumbing contracting business must itself be licensed as a plumbing contractor. Licenses can be checked on the Indiana Professional Licensing Agency's online verification search. Source
  • Indiana codes in effect. Indiana adopts building codes statewide: the 2020 Indiana Residential Code (675 IAC 14-4.4, based on the 2018 IRC) took effect Dec. 26, 2019; the 2012 Indiana Plumbing Code (675 IAC 16-1.4) on Dec. 24, 2012; the 2014 Indiana Mechanical Code (675 IAC 18-1.6) on Dec. 1, 2014; and the Indiana Electrical Code, 2009 Edition (675 IAC 17-1.8, based on the 2008 NEC) on Aug. 26, 2009. Source

Rules change, so check with the department before work starts. A provider can usually tell you whether they pull the permit.

Utilities

  • Chesterton water and sewer providers. In Chesterton, water service is billed by Indiana American Water, while sewer service is billed by the town's Chesterton Utility Department (219-926-1572). Source
  • Water system (EPA map). EPA's community water system boundary map places central Chesterton inside the Indiana American Water - Northwest system (PWSID IN5245015), using a boundary supplied by the system. Source
  • Lake Michigan source. Indiana American Water uses water from two Lake Michigan intakes in northwest Indiana; one of its plants is the Ogden Dunes treatment facility in Portage, which it shut down as a precaution after a 2019 steel mill spill. Source
  • Chesterton wastewater plant. Chesterton's wastewater plant, the Fritz C. Dietrich Environmental Control Facility, serves the Town of Chesterton, the Town of Porter and the Indian Boundary Conservancy District. It treats 4.6 million gallons per day of normal flow and up to 10 million gallons per day during wet weather. Source
  • Chesterton sewer system. Chesterton's sewer collection system has 35 lift stations and more than 68 miles of sanitary sewers, with pipe sizes from 4 to 48 inches. The plant was first built in 1963 and expanded in 1987, 2001 and 2015. Source
  • Sewer and water connections on permits. For new construction, Chesterton requires site plans to show proposed connections to sanitary sewers, storm sewers and potable water, and a building permit application must include sanitary sewer permits as required by the utility. Source
  • Electric provider (IURC map). The Indiana Utility Regulatory Commission's electric service territory map places central Chesterton in the territory of Northern Indiana Public Service Company (NIPSCO). Source
  • Chesterton storm water program. The Town of Chesterton is designated a Municipal Separate Storm Sewer System (MS4) by the Indiana Department of Environmental Management; the MS4 boundary matches the town limits, and the program runs under an NPDES permit renewed every five years. Storm water quality office: 1490 Broadway, Suite 3; 219-728-1336. Source

Flooding

  • East Arm Little Calumet River flood stage at Porter. 8 ft Source
  • Little Calumet flood categories and record. NWS flood categories for the East Arm Little Calumet River at Porter, next to Chesterton, are 7 ft action stage, 8 ft minor, 10.5 ft moderate and 12 ft major flooding. The record crest is 11.3 ft on Sept. 15, 2008; other high crests were 10.96 ft (Oct. 10, 1954) and 10.6 ft (Feb. 21, 2018). Source
  • What flooding reaches in Chesterton. NWS impact statements for the Porter gauge: at 5 ft water overtops low banks in Porter and Chesterton; at 11 ft low-lying parking lots are threatened at St. Patrick Elementary School in Chesterton; at 12 ft structures are threatened at the Dietrich Environmental Control Facility in Porter, and Indian Boundary Road and Brummitt Road may be threatened east of Chesterton; at 14 ft Calumet Road in Chesterton and I-90 are threatened. Source
  • Recent Little Calumet crests. Recent crests on the East Arm Little Calumet River at Porter include 9.44 ft on May 24, 2020, 9.31 ft on Jan. 12, 2020, and 8.74 ft on May 16, 2020, all above the 8 ft flood stage. Source
  • September 2008 rainfall. During the remnants of Hurricane Ike, Sept. 12-15, 2008, NWS Chicago's observer table lists three-day rainfall of 10.59 inches at Chesterton 1.7 WSW and 10.69 inches at Porter 0.6 S. Source
  • FEMA flood map panel. FEMA's National Flood Hazard Layer shows central Chesterton on Flood Insurance Rate Map panel 18127C0131D, a countywide panel effective Sept. 30, 2015. Source
  • Lake Michigan high water. Lake Michigan's record high level is 582.35 ft (October 1986). The lake reached 581.92 ft in July 2019 and peaked near record levels in late 2019 at more than 582 ft, after near-record lows of about 576 ft in 2013. The state says high water drove more storm surge and erosion along the 45-mile Indiana shoreline in Lake, LaPorte and Porter counties, and Executive Order 20-01 (February 2020) directed state agencies to respond. Source
  • Portage-Burns Waterway (Lake Michigan outlet). The Portage-Burns Waterway gauge at the Lake Michigan outlet in Porter County has a 7 ft action stage; its highest recorded crest is 9.93 ft on April 30, 2020, during the period of high Lake Michigan levels. Source
  • Kankakee River near Kouts. NWS flood categories for the Kankakee River near Kouts, along Porter County's southern edge, are 10.5 ft action stage, 11 ft minor, 13 ft moderate and 14 ft major flooding. The record crest is 14.52 ft on March 24, 1982, followed by 14.46 ft on Feb. 26, 2018. Source

Sources